40
4.2.3. Sensor
ON/OFF
Turn on or turn off the sensor
CAMERA
Select the associated camera
OUT
Select the associated alarm output
Caution
Relay contact can handle up to 24V/1A of other devices. If connected to a circuit which is
Over 24V/1A, the system may experience problems.
INTENSIVE
“Intensive” means that the system increases recording speed up to the maximum frame rate at the selected
resolution when an alarm is triggered during the selected dwell time. The recording speed of all other channel
will be automatically decreased during alarm-triggered intensive recording. The unit will also trigger an alarm
signal via the selected sensor-out channel.
PRESET
User can select the camera to move to a preset position, once the sensor is triggered. (User should setup preset
position in PTZ menu 4.2.6 in advance)
DWELL (Post Alarm)
Set the recording period from the start of sensor input activation. During this period, the corresponding camera
video will record according to the frame and alarm (relay) output set. The recording stops and alarm output is
turned off when the dwell time has elapsed.
PRE-ALARM
Set the recording period in seconds just before the alarm-sensor input, up to 3 seconds.
The system records video for the defined amount of pre-alarm so that user can search video even before alarm
is triggered. The pre-alarm recording mode is at the recording that user sets in “record” of “camera” menu.
TYPE
Select the sensor type between N/O(Normal Open) and N/C(Normal Close), connected to the alarm input
terminal. A circuit of N/O type activates the sensor when the circuit closes. An N/C circuit works in the reverse
way.